  • PPS.jpg

PPS FZB1060G

Classification:

PPS

阻燃

Product characteristics

Glass fiber reinforcement/high rigidity/high mechanical strength/low warpage

Scope of application

Electric tools/tray brackets/lampshades

Online Inquiry

Product Description

Physical properties Test Test S.I. S.I.
Standard Condition Unit Data
Mechanical properties
Tensile Strength ISO 527 50mm/min MPa 115.00
tensile strain at break ISO 527 50mm/min % 1.10
Bending strength ISO 178 2mm/min MPa 160.00
flexural modulus ISO 178 2mm/min MPa 14500.00
Izod notched impact strength ISO 180 23 ℃ kJ/m2 6.00
Rockwell hardness ISO 2039-2 R Scale   100
Thermal performance
load thermal deformation temperature ISO 75-2 1.80MPa 260
Electrical Performance
volume resistance IEC 60093   Ω · cm 8E 16
surface resistance IEC 60093   Ω 8E 16
Relative tracking index IEC 60112   PLC CODE 4
dielectric strength IEC 60243   kV/mm 23
Other performance
Density ISO 1183- 1   g/cm3 1.95
glass fiber GB 4609 -- % (65%GF+5%MF)
Molding shrinkage GB1034   % 0.02/td>
water absorption ISO 62 Equilibrium % 0.02
Flammability UL 94 1.6MM / V-0
[1] The above values are typical values, I .e., laboratory average data, which are only used for product development reference and guidance, not as product standards.
[2] The above performance tests are performed at a laboratory temperature of 23°C, unless otherwise specified or specified.
[3] After the color matching of the product, the performance may be different from the above values.

 

Forming processing conditions
  Best Optimum Set Range
melt temperature 290 ℃ 280-320 ℃
Barrel temperature nozzle 310 ℃ 310-320 ℃
Front section 300 ℃ 290-310°C
Middle section 290 ℃ 280-300 ℃
Rear section 280 ℃ 270-290 ℃
Mold temperature 140 ℃ 130-150 ℃
Molding temperature upper limit 340 ℃
Injection speed Medium Speed-Fast
Pre-drying requirements Dehumidification dryer; 120~140 ℃,4~6 hours
[1] The above values are typical values, I .e., laboratory average data, which are only used for product development reference and guidance, not as product standards.
[2] The above performance tests are performed at a laboratory temperature of 23°C, unless otherwise specified or specified.
[3] After the color matching of the product, the performance may be different from the above values.
[4] The values listed may vary depending on the coloring material.
Precautions for safe use
1. Tyco Engineering Plastics Co., Ltd.: The Material Safety Data Sheet (MSDS) of the resin is provided to help customers meet their own needs and meet the requirements of local applicable health and safety regulations of customers, and is only applicable to the resin provided by the company. Various additives and processing aids, other materials used in manufacturing and finishing steps have their own safe use files, and they must be used correctly after investigation;
1. Tyco Engineering Plastics Co., Ltd.: The Material Safety Data Sheet (MSDS) of the resin is provided to help customers meet their own needs and meet the requirements of local applicable health and safety regulations of customers, and is only applicable to the resin provided by the company. Various additives and processing aids, other materials used in manufacturing and finishing steps have their own safe use files, and they must be used correctly after investigation;
2. The overall polymer processing area should be kept well ventilated. The processing process will release smoke including polymer fragments and other decomposition products. The smoke will stimulate human organs. When the temperature exceeds the temperature of the melt, polymer fragments may occur. Ventilation should be adequate in most cases, but certain operations at the place of use may require exhaust ventilation.
3. These resins are very low in toxicity under normal circumstances, and under reasonable conditions of use, they are not easy to cause harm to the human body: such as ingestion of the mouth and nose or with the eyes. Contact with skin, etc. However, it is recommended to use caution. Please use the following protective measures to ensure safety during operation:
1) The operator shall wear gloves with heat insulation protection;
2) Use the eye mask with thermal insulation layer to protect the eyes;
3) Wear an approved mask for mouth and nose for protection;
5. We encourage customers and potential users to use our products:
1) We will carefully review their application needs for such products and strive to meet their views on human health and environmental quality.
2) We also ensure that our products will not be used in the following ways: they are not assumed or untestable, but real and testable;
3) Our personnel will help customers deal with ecological and product safety issues, if necessary, your sales representative can arrange professionals to contact you appropriately.

Key words:

Previous Page

Previous Page

Related Products


undefined

undefined